{"product_id":"victron-energy-multiplus-ii-48500070-95-120v-pure-sine-wave-invertercharger","title":"Victron Energy | MultiPlus-II 48\/5000\/70-95 120V, Pure Sine Wave Inverter\/Charger","description":"\u003ch2 data-start=\"106\" data-end=\"184\"\u003e\u003cstrong data-start=\"109\" data-end=\"184\"\u003eVictron MultiPlus-II 48\/5000\/70-95 120V Pure Sine Wave Inverter\/Charger\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"186\" data-end=\"537\"\u003eThe \u003cstrong data-start=\"190\" data-end=\"225\"\u003eMultiPlus-II 48\/5000\/70-95 120V\u003c\/strong\u003e is Victron Energy’s next-generation inverter\/charger, combining the advanced features of the \u003cstrong data-start=\"319\" data-end=\"332\"\u003eMultiPlus\u003c\/strong\u003e and \u003cstrong data-start=\"337\" data-end=\"350\"\u003eMultiGrid\u003c\/strong\u003e into a powerful, flexible system component. Designed for both off-grid and grid-interactive systems, the MultiPlus-II is ideal for residential and commercial energy storage applications.\u003c\/p\u003e\n\u003cp data-start=\"562\" data-end=\"867\"\u003eThe \u003cstrong data-start=\"566\" data-end=\"582\"\u003eMultiPlus-II\u003c\/strong\u003e inherits all the capabilities of the original MultiPlus, such as true sine wave inversion, adaptive battery charging, and hybrid PowerAssist technology. It also integrates \u003cstrong data-start=\"755\" data-end=\"784\"\u003eanti-islanding protection\u003c\/strong\u003e and a wide range of \u003cstrong data-start=\"805\" data-end=\"840\"\u003ecountry-specific grid approvals\u003c\/strong\u003e from the MultiGrid series.\u003c\/p\u003e\n\u003cp data-start=\"869\" data-end=\"1059\"\u003eIt supports an \u003cstrong data-start=\"884\" data-end=\"927\"\u003eexternal current transformer (optional)\u003c\/strong\u003e, enabling \u003cstrong data-start=\"938\" data-end=\"954\"\u003ePowerControl\u003c\/strong\u003e and \u003cstrong data-start=\"959\" data-end=\"974\"\u003ePowerAssist\u003c\/strong\u003e functions with precise load management and \u003cstrong data-start=\"1018\" data-end=\"1048\"\u003eoptimized self-consumption\u003c\/strong\u003e up to 32A.\u003c\/p\u003e\n\u003ch2 data-start=\"1066\" data-end=\"1086\"\u003e\u003cstrong data-start=\"1070\" data-end=\"1086\"\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1088\" data-end=\"1134\"\u003e\u003cstrong data-start=\"1088\" data-end=\"1132\"\u003ePowerAssist – Prevent AC Source Overload\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1135\" data-end=\"1239\"\u003e\n\u003cli data-start=\"1135\" data-end=\"1239\"\u003e\n\u003cp data-start=\"1137\" data-end=\"1239\"\u003eAutomatically compensates for peak power demands by drawing supplemental energy from the battery bank.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1241\" data-end=\"1286\"\u003e\u003cstrong data-start=\"1241\" data-end=\"1284\"\u003eESS Compatible – Energy Storage Systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1287\" data-end=\"1402\"\u003e\n\u003cli data-start=\"1287\" data-end=\"1402\"\u003e\n\u003cp data-start=\"1289\" data-end=\"1402\"\u003eSeamlessly integrates into grid-tied solar energy systems for self-consumption, time-of-use shifting, and backup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1404\" data-end=\"1447\"\u003e\u003cstrong data-start=\"1404\" data-end=\"1445\"\u003eUninterrupted Power Supply (UPS Mode)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1448\" data-end=\"1647\"\u003e\n\u003cli data-start=\"1448\" data-end=\"1647\"\u003e\n\u003cp data-start=\"1450\" data-end=\"1647\"\u003eIn the event of a grid failure or power source disconnection, the MultiPlus-II ensures seamless switchover to inverter mode (within 20 milliseconds), maintaining continuous power to critical loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1649\" data-end=\"1682\"\u003e\u003cstrong data-start=\"1649\" data-end=\"1680\"\u003eRemote Monitoring \u0026amp; Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1683\" data-end=\"1978\"\u003e\n\u003cli data-start=\"1683\" data-end=\"1855\"\u003e\n\u003cp data-start=\"1685\" data-end=\"1855\"\u003eMonitor and manage system performance from anywhere in the world via the \u003cstrong data-start=\"1758\" data-end=\"1800\"\u003eVictron Remote Management (VRM) portal\u003c\/strong\u003e, when connected to a \u003cstrong data-start=\"1822\" data-end=\"1835\"\u003eGX device\u003c\/strong\u003e (e.g., Cerbo GX).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1856\" data-end=\"1978\"\u003e\n\u003cp data-start=\"1858\" data-end=\"1978\"\u003eAdjust settings, start\/stop backup generators, and analyze detailed energy data using a computer, smartphone, or tablet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1980\" data-end=\"2021\"\u003e\u003cstrong data-start=\"1980\" data-end=\"2019\"\u003eGrid Compliance \u0026amp; Country Approvals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2022\" data-end=\"2188\"\u003e\n\u003cli data-start=\"2022\" data-end=\"2188\"\u003e\n\u003cp data-start=\"2024\" data-end=\"2188\"\u003eIntegrated anti-islanding protection and compatibility with multiple grid standards make the MultiPlus-II suitable for a wide range of energy applications globally.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable cellpadding=\"5\" cellspacing=\"0\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003e12\/3000\/120-50\u003c\/th\u003e\n\u003cth\u003e24\/3000\/70-50\u003c\/th\u003e\n\u003cth\u003e48\/3000\/35-50\u003c\/th\u003e\n\u003cth\u003e48\/5000\/70-95\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePowerControl \u0026amp; PowerAssist\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003e95A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax AC Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003e95A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eINVERTER\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e9.5–17 V\u003c\/td\u003e\n\u003ctd\u003e19–33 V\u003c\/td\u003e\n\u003ctd\u003e38–66 V\u003c\/td\u003e\n\u003ctd\u003e38–66 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage \/ Frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e120 VAC ± 2%, 60 Hz ± 0.1% (1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCont. Output Power at 25°C\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2400 W\u003c\/td\u003e\n\u003ctd\u003e5000 VA \/ 4000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCont. Output Power at 40°C\u003c\/td\u003e\n\u003ctd\u003e2200 W\u003c\/td\u003e\n\u003ctd\u003e2200 W\u003c\/td\u003e\n\u003ctd\u003e2200 W\u003c\/td\u003e\n\u003ctd\u003e3700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCont. Output Power at 65°C\u003c\/td\u003e\n\u003ctd\u003e1700 W\u003c\/td\u003e\n\u003ctd\u003e1700 W\u003c\/td\u003e\n\u003ctd\u003e1700 W\u003c\/td\u003e\n\u003ctd\u003e3000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power\u003c\/td\u003e\n\u003ctd\u003e5500 W\u003c\/td\u003e\n\u003ctd\u003e5500 W\u003c\/td\u003e\n\u003ctd\u003e5500 W\u003c\/td\u003e\n\u003ctd\u003e9000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Efficiency\u003c\/td\u003e\n\u003ctd\u003e93%\u003c\/td\u003e\n\u003ctd\u003e94%\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003ctd\u003e96%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Load Power\u003c\/td\u003e\n\u003ctd\u003e13 W\u003c\/td\u003e\n\u003ctd\u003e13 W\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Load Power (AES Mode)\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003ctd\u003e7 W\u003c\/td\u003e\n\u003ctd\u003e10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Load Power (Search Mode)\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eCHARGER\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e90–140 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e45–65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge Voltage 'Absorption'\u003c\/td\u003e\n\u003ctd\u003e14.4 V\u003c\/td\u003e\n\u003ctd\u003e28.8 V\u003c\/td\u003e\n\u003ctd\u003e57.6 V\u003c\/td\u003e\n\u003ctd\u003e57.6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge Voltage 'Float'\u003c\/td\u003e\n\u003ctd\u003e13.8 V\u003c\/td\u003e\n\u003ctd\u003e27.6 V\u003c\/td\u003e\n\u003ctd\u003e55.2 V\u003c\/td\u003e\n\u003ctd\u003e55.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Mode\u003c\/td\u003e\n\u003ctd\u003e13.2 V\u003c\/td\u003e\n\u003ctd\u003e26.4 V\u003c\/td\u003e\n\u003ctd\u003e52.8 V\u003c\/td\u003e\n\u003ctd\u003e52.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Battery Charge Current\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003ctd\u003e70 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003ctd\u003e70 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Temperature Sensor\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eGENERAL\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Output (5)\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003ctd\u003e48 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal AC Current Sensor (Optional)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Relay (6)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ea – g (see note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVE.Bus Communication\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eFor parallel, split phase \u0026amp; 3-phase operation, monitoring \u0026amp; integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Purpose Comm. Ports\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eYes, 2x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote On\/Off\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-40 to +60°C (-40 to 140°F), fan-assisted cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Humidity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eENCLOSURE\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial \u0026amp; Colour\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eSteel, blue (RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Category\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Connection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eM8 bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Connection\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e13 mm² (6 AWG)\u003c\/td\u003e\n\u003ctd\u003e35 mm² (2 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e19 kg \/ 42 lb\u003c\/td\u003e\n\u003ctd\u003e19 kg \/ 42 lb\u003c\/td\u003e\n\u003ctd\u003e19 kg \/ 42 lb\u003c\/td\u003e\n\u003ctd\u003e32 kg \/ 71 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e578×277×148 mm\u003cbr\u003e22.8×10.9×5.8 in\u003c\/td\u003e\n\u003ctd\u003e536×277×147 mm\u003cbr\u003e21.1×10.9×5.8 in\u003c\/td\u003e\n\u003ctd\u003e572×277×147 mm\u003cbr\u003e22.5×10.9×5.8 in\u003c\/td\u003e\n\u003ctd\u003e676×330×164 mm\u003cbr\u003e26.6×13.0×6.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eSTANDARDS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListings\u003c\/td\u003e\n\u003ctd\u003eUL458\u003c\/td\u003e\n\u003ctd\u003eUL458\u003c\/td\u003e\n\u003ctd\u003eUL1741\u003c\/td\u003e\n\u003ctd\u003eUL1741 (pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eEN-IEC 60335-1\/2-29, CSA 22.2 107.1-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmission, Immunity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eEN 55014-1\/2, EN-IEC 61000-3-2\/3,\u003cbr\u003eIEC 61000-6-1\/2\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eNOTES\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e1) Frequency adjustable to 50 Hz\u003cbr\u003e2) Protections: a) short circuit, b) overload, c) battery voltage too high, d) battery voltage too low, e) temp. too high, f) 120 VAC on output, g) input voltage ripple too high\u003cbr\u003e3) Values based on non-linear load (crest factor 3:1)\u003cbr\u003e4) Rated at 25°C ambient\u003cbr\u003e5) Aux output disabled when no external AC source\u003cbr\u003e6) Relay configurable for alarm, DC undervoltage, or genset start\/stop (AC: 120V\/4A, DC: 4A@35V, 1A@60V)\u003cbr\u003e7) Comm. with Lithium-Ion BMS supported\u003cbr\u003e8) 48\/3000\/35-50 non-UL1741 model: 536×277×147 mm \/ 21.1×10.9×5.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eManuals and Downloads\u003c\/h3\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0775\/1398\/2234\/files\/MultiPlus-II___Quattro-II_120V-230V-en_9646709f-0749-4901-bc33-17897ae5eb69.pdf?v=1744998923\" target=\"_blank\"\u003eManual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0775\/1398\/2234\/files\/Datasheet-MultiPlus-II-3kVA-2x120V-EN_aa257bc5-839d-4235-88ef-c47f88cb78cb.pdf?v=1744998922\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e","brand":"castelow","offers":[{"title":"Default Title","offer_id":67597875052860,"sku":"PMP482505110","price":1021.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0998\/3449\/5292\/files\/Victron-Energy-MultiPlus-II-12-3000-120-50-2x120V-0_6ce82f0f-4950-4b6b-9d96-a13744d2313b.webp?v=1790632632","url":"https:\/\/castelow.shop\/products\/victron-energy-multiplus-ii-48500070-95-120v-pure-sine-wave-invertercharger","provider":"castelow","version":"1.0","type":"link"}