Regular price $1,021.02 Save $-1,021.02Victron MultiPlus-II 48/5000/70-95 120V Pure Sine Wave Inverter/Charger
The MultiPlus-II 48/5000/70-95 120V is Victron Energy’s next-generation inverter/charger, combining the advanced features of the MultiPlus and MultiGrid into a powerful, flexible system component. Designed for both off-grid and grid-interactive systems, the MultiPlus-II is ideal for residential and commercial energy storage applications.
The MultiPlus-II inherits all the capabilities of the original MultiPlus, such as true sine wave inversion, adaptive battery charging, and hybrid PowerAssist technology. It also integrates anti-islanding protection and a wide range of country-specific grid approvals from the MultiGrid series.
It supports an external current transformer (optional), enabling PowerControl and PowerAssist functions with precise load management and optimized self-consumption up to 32A.
Key Features
PowerAssist – Prevent AC Source Overload
-
Automatically compensates for peak power demands by drawing supplemental energy from the battery bank.
ESS Compatible – Energy Storage Systems
-
Seamlessly integrates into grid-tied solar energy systems for self-consumption, time-of-use shifting, and backup.
Uninterrupted Power Supply (UPS Mode)
-
In the event of a grid failure or power source disconnection, the MultiPlus-II ensures seamless switchover to inverter mode (within 20 milliseconds), maintaining continuous power to critical loads.
Remote Monitoring & Control
-
Monitor and manage system performance from anywhere in the world via the Victron Remote Management (VRM) portal, when connected to a GX device (e.g., Cerbo GX).
-
Adjust settings, start/stop backup generators, and analyze detailed energy data using a computer, smartphone, or tablet.
Grid Compliance & Country Approvals
-
Integrated anti-islanding protection and compatibility with multiple grid standards make the MultiPlus-II suitable for a wide range of energy applications globally.
Specification
| Specification | 12/3000/120-50 | 24/3000/70-50 | 48/3000/35-50 | 48/5000/70-95 |
|---|---|---|---|---|
| PowerControl & PowerAssist | Yes | |||
| Transfer Switch | 50A | 50A | 50A | 95A |
| Max AC Input Current | 50A | 50A | 50A | 95A |
| INVERTER | ||||
| DC Input Voltage Range | 9.5–17 V | 19–33 V | 38–66 V | 38–66 V |
| Output Voltage / Frequency | 120 VAC ± 2%, 60 Hz ± 0.1% (1) | |||
| Cont. Output Power at 25°C | 3000 VA / 2400 W | 3000 VA / 2400 W | 3000 VA / 2400 W | 5000 VA / 4000 W |
| Cont. Output Power at 40°C | 2200 W | 2200 W | 2200 W | 3700 W |
| Cont. Output Power at 65°C | 1700 W | 1700 W | 1700 W | 3000 W |
| Peak Power | 5500 W | 5500 W | 5500 W | 9000 W |
| Maximum Efficiency | 93% | 94% | 95% | 96% |
| Zero Load Power | 13 W | 13 W | 11 W | 15 W |
| Zero Load Power (AES Mode) | 9 W | 9 W | 7 W | 10 W |
| Zero Load Power (Search Mode) | 3 W | 3 W | 2 W | 3 W |
| CHARGER | ||||
| Input Voltage Range | 90–140 VAC | |||
| Input Frequency | 45–65 Hz | |||
| Charge Voltage 'Absorption' | 14.4 V | 28.8 V | 57.6 V | 57.6 V |
| Charge Voltage 'Float' | 13.8 V | 27.6 V | 55.2 V | 55.2 V |
| Storage Mode | 13.2 V | 26.4 V | 52.8 V | 52.8 V |
| Max Battery Charge Current | 120 A | 70 A | 35 A | 70 A |
| Battery Temperature Sensor | Yes | |||
| GENERAL | ||||
| Auxiliary Output (5) | 32 A | 32 A | 32 A | 48 A |
| External AC Current Sensor (Optional) | 100 A | |||
| Programmable Relay (6) | Yes | |||
| Protection | a – g (see note) | |||
| VE.Bus Communication | For parallel, split phase & 3-phase operation, monitoring & integration | |||
| General Purpose Comm. Ports | Yes, 2x | |||
| Remote On/Off | Yes | |||
| Operating Temperature | -40 to +60°C (-40 to 140°F), fan-assisted cooling | |||
| Max Humidity | 95% (non-condensing) | |||
| ENCLOSURE | ||||
| Material & Colour | Steel, blue (RAL 5012) | |||
| Protection Category | IP22 | |||
| Battery Connection | M8 bolts | |||
| AC Connection | 13 mm² (6 AWG) | 35 mm² (2 AWG) | ||
| Weight | 19 kg / 42 lb | 19 kg / 42 lb | 19 kg / 42 lb | 32 kg / 71 lb |
| Dimensions (HxWxD) | 578×277×148 mm 22.8×10.9×5.8 in |
536×277×147 mm 21.1×10.9×5.8 in |
572×277×147 mm 22.5×10.9×5.8 in |
676×330×164 mm 26.6×13.0×6.5 in |
| STANDARDS | ||||
| Listings | UL458 | UL458 | UL1741 | UL1741 (pending) |
| Safety | EN-IEC 60335-1/2-29, CSA 22.2 107.1-16 | |||
| Emission, Immunity | EN 55014-1/2, EN-IEC 61000-3-2/3, IEC 61000-6-1/2/3 |
|||
| NOTES | ||||
| 1) Frequency adjustable to 50 Hz 2) Protections: a) short circuit, b) overload, c) battery voltage too high, d) battery voltage too low, e) temp. too high, f) 120 VAC on output, g) input voltage ripple too high 3) Values based on non-linear load (crest factor 3:1) 4) Rated at 25°C ambient 5) Aux output disabled when no external AC source 6) Relay configurable for alarm, DC undervoltage, or genset start/stop (AC: 120V/4A, DC: 4A@35V, 1A@60V) 7) Comm. with Lithium-Ion BMS supported 8) 48/3000/35-50 non-UL1741 model: 536×277×147 mm / 21.1×10.9×5.8 in |
||||